- Albany Ultrasmart Controller Operation Manual 2016
- Albany Ultrasmart Controller Operation Manual Software
- Albany Ultrasmart Controller Operation Manual Online
Download Owner's manual of Albany 570 Door, Garage Door Opener for Free or View it Online on All-Guides.com.
Download 11 Albany Door PDF manuals. User manuals, Albany Door Operating guides and Service manuals. UltraFabric Doors w/ UltraSmart Operation - Albany. ACS-50 CONTROL PANEL ALBANY DOOR SYSTEMS 975-A Old Norcross Road Lawrenceville, GA. If you cannot answer “yes” to all the above questions, check all wiring connections and ensure the RFID is set to the same number that is labeled on the wireless bottom bar module. 17 Manual #001011 Rev. 4/29/2010 Albany High Speed Doors Operation UltraSmart™ STARTUP PROCEDURE Albany’s UltraSmart™ control system is designed to.
Brand: Albany
Category: Door , Garage Door Opener
Type: Owner's manual
Model: Albany 570 , Albany RapidRoll 670
Pages: 56 (2.97 Mb)
Part Number 6410T0006 Version 4/23/2010
CHAIN DRIVE INSTALLATION
This option adds a bracket and chain drive sprockets to remote the standard drive unit out in front of the
door top roll. It is used in applications with limited side room clearance. This option is not available
NOTE
REFERENCE FIGURE 29 WHILE PERFORMING THIS PROCEDURE
Related Products for Albany RapidRoll 670
Albany Ultrasmart Controller Operation Manual 2016
Related Manuals for Albany RapidRoll 670
Albany RapidRoll 670: Frequently viewed Manuals
Download Owner's manual of Albany 570 Door, Garage Door Opener for Free or View it Online on All-Guides.com.
Brand: Albany
Albany Ultrasmart Controller Operation Manual Software
Category: Door , Garage Door Opener Imgburn full version.
Lounge lizard vst torrent. Type: Owner's manual
Model: Albany 570 , Albany RapidRoll 670
Pages: 56 (2.97 Mb)
Part Number 6410T0006 Version 4/23/2010
The motor brake is located inside the fan cover compartment of the motor. It can be accessed by
removing the fan cover. Refer to Figure 28 while following this procedure.
Albany Ultrasmart Controller Operation Manual Online
WARNING
MAKE SURE THE DOOR IS POWERED DOWN AND LOCKD OUT BEFORE REMOVING THE
FANCOVER. THIS IS TO ASSURE THAT THE MOVING MOTOR PARTS ARE NOT EXPOSED
1.Remove the fan cover
3.Set the air gap “T” (referred to Figure 28) to 0.3mm by adjusting the screw referred to in Figure 28
4.Tighten nut (referred to in Figure 28as item 6) to lock in the gap setting.
5.Verify that the gap “X” (referred to Figure 28) is a minimum of 1.0mm by adjusting the nut shown.
Perform this procedure whenever the gap “T” grows above 0.45mm.